Wind turbines can be connected to ac system at different voltage levels. The voltage level depends on the amount of power generated. Following are the main issues need to be considered while interconnecting wind power system to the grid.
But the disadvantage of the system having converters is that they produces harmonic distortions in the system.
Reserve capacity is used to ensure reliable operation of individual networks. Due to grid interconnections reserve requirement need reduces and pooling reserve increases this causes most reliable operation of electrical power network.
Due to grid interconnection reserve required is less. This will reduces requirement or need of new generating capacity which ultimately reduces the investment needed for new addition of generator.
As due to grid interconnection, requirement of new generator reduces. This will reduces the construction cost required for addition of new generator in existing power plant and development of new generation power plant.
Grid interconnections allow planned outages of generators for maintenance purpose between interconnected power plants. Due to this overall cost decreases for maintenance
and improves reliability.
Grid interconnection permits the use of power plants having lower environmental impacts like renewable energy power plants etc.
Gird interconnection permits the power generation from least costly generating units within the interconnected area. It means that, lower expensive power sold from one system to other system.
Power system can operate at most economic power dispatch provided power demand should be steady over time without high peak values. Load factor is defined as
Load factor = Average power Demand / peak power demand
Load factor = Average Power Demand / Peak Power Demand
Poor or less load means need of larger generation capacity to supply peak demand. Interconnection allows to supply the peak power demand of one system from other system, this reduces the need of newer generating power plant. Thus it improves the load factor and improves the load diversity.
Generation system using different fuels for generation of power it connected to the grid provides and assures more energy or power security in the event of failure of one system. Thus larger and more different generation mix improves reliability.
9.It helps in maintaining power load balance with the use of battery energy storage system (BESS).